{"id":4941,"date":"2023-08-03T16:34:50","date_gmt":"2023-08-03T16:34:50","guid":{"rendered":"https:\/\/www.lifescienceart.com\/?p=4941"},"modified":"2023-08-03T16:34:50","modified_gmt":"2023-08-03T16:34:50","slug":"national-electrical-code-nec-rules-for-outdoor-wiring","status":"publish","type":"post","link":"https:\/\/www.lifescienceart.com\/ro\/life\/home-improvement\/national-electrical-code-nec-rules-for-outdoor-wiring\/","title":{"rendered":"Regulile NEC: Ghidul dvs. pentru cablarea exterioar\u0103 \u00een siguran\u021b\u0103"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Regulile Codului Na\u021bional Electric (NEC) pentru cablarea exterioar\u0103<\/h2>\n\n<h2 class=\"wp-block-heading\">Prize exterioare<\/h2>\n\n<p>NEC include reguli specifice pentru instalarea prizelor exterioare pentru a asigura siguran\u021ba \u0219i a preveni riscurile de \u0219oc electric. Aceste reguli includ:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>Protec\u021bie GFCI:<\/strong> Toate prizele exterioare trebuie s\u0103 aib\u0103 protec\u021bie cu \u00eentrerup\u0103tor de circuit de defect la mas\u0103 (GFCI) pentru a preveni electrocutarea.<\/li>\n<li><strong>Accesibilitate:<\/strong> Casele trebuie s\u0103 aib\u0103 cel pu\u021bin o priz\u0103 exterioar\u0103 \u00een fa\u021b\u0103 \u0219i \u00een spate, u\u0219or accesibil\u0103 de la sol \u0219i nu mai mult de 6 1\/2 picioare deasupra nivelului solului.<\/li>\n<li><strong>Prize de teras\u0103 \u0219i balcon:<\/strong> Terasele \u0219i balcoanele ata\u0219ate cu acces interior trebuie s\u0103 aib\u0103 o priz\u0103 nu mai mare de 6 1\/2 picioare deasupra suprafe\u021bei de mers.<\/li>\n<li><strong>Rezisten\u021b\u0103 la intemperii:<\/strong> Prizele din loca\u021bii umede (sub capace de protec\u021bie) trebuie s\u0103 fie rezistente la intemperii, cu un capac rezistent la intemperii.<\/li>\n<li><strong>Loca\u021bii umede:<\/strong> Prizele din loca\u021bii umede (expuse la intemperii) trebuie s\u0103 fie rezistente la intemperii, cu un capac &#8220;\u00een uz&#8221; rezistent la intemperii.<\/li>\n<li><strong>Accesul la piscin\u0103:<\/strong> O piscin\u0103 permanent\u0103 trebuie s\u0103 aib\u0103 acces la o priz\u0103 protejat\u0103 GFCI nu mai aproape de 6 picioare \u0219i nu mai departe de 20 de picioare de marginea piscinei, nu mai mare de 6 1\/2 picioare deasupra pun\u021bii piscinei.<\/li>\n<li><strong>Sisteme de pompare:<\/strong> Prizele pentru sistemele de pompare a piscinei \u0219i a spa-ului trebuie s\u0103 fie la cel pu\u021bin 10 picioare de piscine \u0219i spa-uri, dac\u0103 nu sunt protejate GFCI \u0219i la cel pu\u021bin 6 picioare distan\u021b\u0103, dac\u0103 sunt protejate GFCI.<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">Iluminat exterior<\/h2>\n\n<p>NEC ofer\u0103, de asemenea, reguli pentru iluminatul exterior pentru a asigura siguran\u021ba \u0219i iluminarea corespunz\u0103toare. Aceste reguli includ:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>Evaluarea loca\u021biei:<\/strong> Corpurile de iluminat din zonele umede\/expuse trebuie s\u0103 fie listate pentru utilizare \u00een loca\u021bii umede. Corpurile de iluminat din zonele umede (protejate de o strea\u0219in\u0103 sau acoperi\u0219) trebuie s\u0103 fie listate pentru zone umede.<\/li>\n<li><strong>Cutii montate pe suprafa\u021b\u0103:<\/strong> Cutiile electrice pentru toate corpurile de iluminat exterioare trebuie s\u0103 fie etan\u0219e\/rezistente la intemperii.<\/li>\n<li><strong>Protec\u021bie GFCI:<\/strong> Corpurile de iluminat exterioare nu necesit\u0103 protec\u021bie GFCI.<\/li>\n<li><strong>Iluminat de joas\u0103 tensiune:<\/strong> Sistemele de iluminat de joas\u0103 tensiune trebuie s\u0103 fie listate de o agen\u021bie de testare aprobat\u0103 \u0219i instalate conform instruc\u021biunilor produc\u0103torului.<\/li>\n<li><strong>Proximitatea piscinelor:<\/strong> Corpurile de iluminat de joas\u0103 tensiune trebuie s\u0103 fie la cel pu\u021bin 5 picioare distan\u021b\u0103 de pere\u021bii exteriori ai piscinelor, spa-urilor sau c\u0103zilor cu hidromasaj.<\/li>\n<li><strong>Plasarea transformatorului:<\/strong> Transformatoarele pentru iluminat de joas\u0103 tensiune trebuie s\u0103 fie amplasate \u00een zone accesibile.<\/li>\n<li><strong>Loca\u021bia \u00eentrerup\u0103torului:<\/strong> \u00centrerup\u0103toarele care controleaz\u0103 luminile sau pompele piscinei sau spa-ului trebuie s\u0103 fie la cel pu\u021bin 5 picioare de pere\u021bii exteriori ai piscinei sau spa-ului, cu excep\u021bia cazului \u00een care sunt separate printr-un perete.<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">Cabluri \u0219i conducte exterioare<\/h2>\n\n<p>NEC reglementeaz\u0103 utilizarea cablurilor \u0219i conductelor pentru cablarea exterioar\u0103 pentru a asigura siguran\u021ba electric\u0103 \u0219i protec\u021bia \u00eempotriva umezelii \u0219i a deterior\u0103rii. Aceste reguli includ:<\/p>\n\n<ul class=\"wp-block-list\">\n<li><strong>Cablare expus\u0103:<\/strong> Cablajul\/cablurile expuse sau \u00eengropate trebuie s\u0103 fie listate pentru uz exterior. Cablul de tip UF este utilizat \u00een mod obi\u0219nuit pentru cabl\u0103rile exterioare reziden\u021biale.<\/li>\n<li><strong>\u00cengropare subteran\u0103:<\/strong> Cablul UF poate fi \u00eengropat direct f\u0103r\u0103 conduct\u0103, cu un minim de 24 de inci de acoperire cu p\u0103m\u00e2nt.<\/li>\n<li><strong>Utilizarea conductei:<\/strong> Cablajul \u00eengropat \u00een conduct\u0103 metalic\u0103 rigid\u0103 (RMC) sau conduct\u0103 metalic\u0103 intermediar\u0103 (IMC) trebuie s\u0103 aib\u0103 cel pu\u021bin 6 inci de acoperire cu p\u0103m\u00e2nt; cablajul \u00een conduct\u0103 PVC trebuie s\u0103 aib\u0103 cel pu\u021bin 18 inci de acoperire.<\/li>\n<li><strong>Umplutura:<\/strong> Umplutura din jurul conductei sau cablurilor trebuie s\u0103 fie material granular neted, f\u0103r\u0103 roci.<\/li>\n<li><strong>Cablare de joas\u0103 tensiune:<\/strong> Cablajul de joas\u0103 tensiune (care nu transport\u0103 mai mult de 30 de vol\u021bi) trebuie s\u0103 fie \u00eengropat la cel pu\u021bin 6 inci ad\u00e2ncime.<\/li>\n<li><strong>Tranzi\u021bii de la subteran la suprateran:<\/strong> Traseele de cabluri \u00eengropate care trec de la subteran la suprateran trebuie protejate \u00eentr-o conduct\u0103 de la ad\u00e2ncimea de acoperire necesar\u0103 sau 18 inci (oricare este mai mic\u0103) p\u00e2n\u0103 la punctul lor de terminare deasupra solului sau cel pu\u021bin 8 picioare deasupra nivelului solului.<\/li>\n<li><strong>Cabluri de service electric:<\/strong> Cablurile de service electric care at\u00e2rn\u0103 deasupra unei piscine, a unui spa sau a unei c\u0103zi cu hidromasaj trebuie s\u0103 fie la cel pu\u021bin 22 1\/2 picioare deasupra suprafe\u021bei apei sau a platformei de scufund\u0103ri.<\/li>\n<li><strong>Cabluri de transmisie de date:<\/strong> Cablurile de transmisie a datelor trebuie s\u0103 fie la cel pu\u021bin 10 picioare deasupra suprafe\u021bei apei \u00een piscine, spa-uri \u0219i c\u0103zi cu hidromasaj.<\/li>\n<\/ul>\n\n<h2 class=\"wp-block-heading\">Suna\u021bi \u00eenainte de a s\u0103pa<\/h2>\n\n<p>\u00cenainte de a s\u0103pa oriunde pe proprietatea dvs., suna\u021bi la 811, linia fierbinte na\u021bional\u0103 \u201eSuna\u021bi \u00eenainte de a s\u0103pa\u201d, pentru a preveni deteriorarea utilit\u0103\u021bilor subterane \u0219i posibilele r\u0103niri. Furnizorii de utilit\u0103\u021bi \u00ee\u0219i vor marca liniile, permi\u021b\u00e2ndu-v\u0103 s\u0103 s\u0103pa\u021bi \u00een siguran\u021b\u0103.<\/p>","protected":false},"excerpt":{"rendered":"<p>Regulile Codului Na\u021bional Electric (NEC) pentru cablarea exterioar\u0103 Prize exterioare NEC include reguli specifice pentru instalarea prizelor exterioare pentru a asigura siguran\u021ba \u0219i a preveni riscurile de \u0219oc electric. Aceste&hellip;<\/p>\n","protected":false},"author":4,"featured_media":0,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[8844],"tags":[8842,8841,8843,8840],"class_list":["post-4941","post","type-post","status-publish","format-standard","hentry","category-home-improvement","tag-nec-compliance","tag-outdoor-wiring","tag-home-safety","tag-electrical-safety"],"_links":{"self":[{"href":"https:\/\/www.lifescienceart.com\/ro\/wp-json\/wp\/v2\/posts\/4941","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lifescienceart.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.lifescienceart.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.lifescienceart.com\/ro\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lifescienceart.com\/ro\/wp-json\/wp\/v2\/comments?post=4941"}],"version-history":[{"count":1,"href":"https:\/\/www.lifescienceart.com\/ro\/wp-json\/wp\/v2\/posts\/4941\/revisions"}],"predecessor-version":[{"id":4942,"href":"https:\/\/www.lifescienceart.com\/ro\/wp-json\/wp\/v2\/posts\/4941\/revisions\/4942"}],"wp:attachment":[{"href":"https:\/\/www.lifescienceart.com\/ro\/wp-json\/wp\/v2\/media?parent=4941"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.lifescienceart.com\/ro\/wp-json\/wp\/v2\/categories?post=4941"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.lifescienceart.com\/ro\/wp-json\/wp\/v2\/tags?post=4941"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}